SHOP ONLINE NOW
Our E-Commerce Site is now live. You can view pricing and place orders directly online.
Siemens - 6SL3244-0BB12-1FA0 SINAMICS G120 CONTROL UNIT CU240E-2 PN E-TYPE SAFETY INTEGRATED STO PROFINET 6DI, 3DO, 2AI, 2AO, MAX 1F-DI PTC/KTY INTERFACE USB- AND SD/MMC-INTERFACE PROTECTION IP20 AMBIENT TEMP 0 TO +50 DEG C WITHOUT POWER MODULE AND PANEL
6SL32440BB121FA0
Manufacturer: Siemens
SINAMICS G120 CONTROL UNIT CU240E-2 PN E-TYPE SAFETY INTEGRATED STO PROFINET 6DI, 3DO, 2AI, 2AO, MAX 1F-DI PTC/KTY INTERFACE USB- AND SD/MMC-INTERFACE PROTECTION IP20 AMBIENT TEMP 0 TO +50 DEG C WITHOUT POWER MODULE AND PANEL
Available for Back Order
Estimated lead time: 9 to 10 days | Check Availability
SINAMICS G120 CONTROL UNIT CU240E-2 PN E-TYPE SAFETY INTEGRATED STO PROFINET 6DI, 3DO, 2AI, 2AO, MAX 1F-DI PTC/KTY INTERFACE USB- AND SD/MMC-INTERFACE PROTECTION IP20 AMBIENT TEMP 0 TO +50 DEG C WITHOUT POWER MODULE AND PANEL Control Unit SINAMICS CU240E-2 PN Control Unit for standard applications in general machinery construction for modular SINAMICS G120 inverters. The CU240E-2 Control Unit is part of the modular SINAMICS G120 inverter (comprising power unit, control unit, operator panel).The control unit is designed for all of the usual applications with U/f or vector control. These include encoderless basic applications in general machinery construction, for example.The CU240E-2 is equipped as standard with the integrated Safe Torque Off (STO) safety function.Further, the control unit has the integrated SS1, SLS, SDI and SSM safety functions, allowing it to address a wide range of applications.The CU240E-2 Control Unit controls and monitors the power unit (Power Module) and the connected motor; several control modes can be selected. It facilitates communication to a local or central control system as well as to the monitoring equipment – and is used to connect all process-related auxiliary equipment and external components (sensors, valves, contactors, etc.)The I/O interface, the fieldbus interfaces and the additional software functions optimally support its use in general machinery construction.For intuitive series commissioning, a card slot is provided for cloning parameters sets. The communication interface of the inverter is defined when selecting the CU240E-2. The following integrated communication versions are available: CU240E-2 with USS and Modbus RTU protocols, CU240E-2 DP PROFIBUS and CU240E-2 PN PROFINET,EtherNet/IP. The Control Unit can be operated with the following SINAMICS power units: PM240-2 (0.55 kW to 132 kW) and PM240 (up to 250 kW). SINAMICS - simply my drive!
Datasheets and Manuals
Product Information
Manufacturer: | Siemens |
Pricing Unit: | Each |
Tariff code: | 85049099 |
Generic code: | 342 |
GTIN/UPC/EAN: | 4042948661864 |
Product Details
ETIM Group: | Low-voltage industrial components |
ETIM Class: | Frequency converter =< 1 kV |
4-quadrant operation possible: | - |
Application in domestic- and commercial area permitted: | - |
Application in industrial area permitted: | - |
Degree of protection (NEMA): | 1 |
Depth: | 46mm |
Height: | 199mm |
Integrated breaking resistance: | - |
Mains voltage: | - - |
Max. output at linear load at rated output voltage: | - |
Max. output at quadratic load at rated output voltage: | - |
Max. output frequency: | - |
Max. output voltage: | - |
Nominal output current I2N: | - |
Number of analogue inputs: | 2 |
Number of analogue outputs: | 2 |
Number of digital inputs: | 6 |
Number of digital outputs: | 3 |
Number of HW-interfaces industrial Ethernet: | 2 |
Number of HW-interfaces other: | - |
Number of HW-interfaces parallel: | 0 |
Number of HW-interfaces RS-232: | 1 |
Number of HW-interfaces RS-422: | 0 |
Number of HW-interfaces RS-485: | 0 |
Number of HW-interfaces serial TTY: | 4 |
Number of HW-interfaces USB: | 1 |
Number of interfaces PROFINET: | 2 |
Relative symmetric net frequency tolerance: | - |
Relative symmetric net voltage tolerance: | - |
Supporting protocol for ASI: | false |
Supporting protocol for AS-Interface Safety at Work: | false |
Supporting protocol for BACnet: | false |
Supporting protocol for CAN: | false |
Supporting protocol for Data-Highway: | false |
Supporting protocol for DeviceNet: | false |
Supporting protocol for DeviceNet Safety: | false |
Supporting protocol for EtherNet/IP: | true |
Supporting protocol for Foundation Fieldbus: | false |
Supporting protocol for INTERBUS: | false |
Supporting protocol for INTERBUS-Safety: | false |
Supporting protocol for KNX: | false |
Supporting protocol for LON: | false |
Supporting protocol for Modbus: | false |
Supporting protocol for other bus systems: | false |
Supporting protocol for PROFIBUS: | false |
Supporting protocol for PROFINET CBA: | false |
Supporting protocol for PROFINET IO: | false |
Supporting protocol for PROFIsafe: | true |
Supporting protocol for SafetyBUS p: | false |
Supporting protocol for SERCOS: | false |
Supporting protocol for SUCONET: | false |
Supporting protocol for TCP/IP: | true |
Width: | 73mm |
With control element: | - |
With optical interface: | false |
With PC connection: | true |
Dimensions (Unpackaged)
Quantity | Height | Width | Length | Weight |
---|---|---|---|---|
1 | 210 mm | 70 mm | 45 mm | 500 g |
All shipping options below are for United Arab Emirates. Delivery prices below are Exc VAT.
Web Promo Carriage | UK standard delivery, usually within 1 - 2 days (1 per day, minimum order AED 2,000.00) | AED 0.00 |
Standard 1-2 Days | UAE standard delivery, usually within 1 - 2 days | AED 25.00 |
Collect | Collection is available from our site - please call if your order is urgent | AED 0.00 |
International Priority to Bahrain
from AED 254.34
(Terms DAP to Delivery Address)
For our overseas customers, we offer a very competitive and fast delivery service; however, if you prefer to collect using your own courier, then we can also arrange that at no extra cost.
Our technical team can help find an alternative! Fill in the below to get started.